Glove compartment: Difference between revisions
Jump to navigation
Jump to search
Line 134: | Line 134: | ||
To replace worn release button cap the whole lock cylinder has to be replaced (part number A2206800784 + color code) for around EUR 100. | To replace worn release button cap the whole lock cylinder has to be replaced (part number A2206800784 + color code) for around EUR 100. | ||
The lock mechanism must be removed and transferred to the new part. | The lock mechanism must be removed and transferred to the new part. | ||
<!-- http://www.mbclub.co.uk/forums/2081547-post9.html --> | |||
{| | {| |
Revision as of 23:26, 18 March 2017
Removing and installing glove compartment
|
|
- Open glove compartment lid (6)
- Unclip glove compartment lamp (1) and disconnect connector
- Remove plugs (2)
- Unscrew screws (3)
- Unscrew screws (4)
- Pull glove compartment (5) completely out of instrument panel
- Unhook control cable (7) on lock (8) on glove compartment (5). When unhooking the control cable (7) ensure that the slider (arrow) is not pulled out of the lock (8).
- Install in opposite order
Removing and installing lock cylinder on glove compartment lid
|
- Remove glove compartment
- Unscrew mounting screws for lock cylinder (1). Lock cylinder (1) is screwed onto instrument panel (2) from rear.
- Remove lock cylinder (1) to side
- Unhook control cable from eye (arrow) on lock cylinder (1). Installation: Check function of control cable, adjust with knurled nut if necessary.
- Install in opposite order
Removing and installing glove compartment lid
|
|
- Remove glove compartment (2)
- Unclip damping strip (8) on right from strap (5), (arrow) on glove compartment lid (1)
- Remove rubber stops (3) from strap (5)
- Pull expanding anchor (4) out of glove compartment (2). Pull expanding anchor out of glove compartment from inside.
- Remove glove compartment lid (1) together with hinges (6) uniformly downward
- Install in opposite order
- Adjust glove compartment lid
Disassembling and reassembling glove compartment lid
|
Adjusting glove compartment lid
|
During entire operation pay attention to uniform transition and gap all the way around (arrows) on the glove compartment lid (1) in relation to the instrument panel (2).
- Pull out both expanding anchors (3) from glove compartment lid (4) with small screwdriver
- Close glove compartment lid (1), adjust horizontal gap and transitions (arrows). Glove compartment lid (1) can be adjusted increment for increment on the hinge.
- Carefully open glove compartment lid (1) and press in expanding anchors (3)
- Check gap width at side, adjust.
- Differences in the gap width can be corrected slightly by loosening the mounting screws (4 each) for the glove compartment (4) and then moving.
- Check transition from glove compartment lid (1) to instrument panel (2), adjust. Adjustment is possible by screwing the two stop screws (5) in or out.
- Check for easy motion and proper function
Parts
Worn glove box release button
Very popular issue is worn glove box release button. The color layer after years peals off leaving the plastic cap visible.
Worn cap on the key block can be replaced by ordering the cap (part number A2206890330 + color code) for around EUR 6.
To replace worn release button cap the whole lock cylinder has to be replaced (part number A2206800784 + color code) for around EUR 100. The lock mechanism must be removed and transferred to the new part.