'''M113 Coolant Change Interval'''
* OEM Coolant is supposedly good for 250,000Km or 15 Years.
* M-B DIY enthusiasts typically change the coolant every 3 - 5 years.
'''M113 Coolant Quantity Required'''
* Cooling System Capacity is 11.2L.


'''M-B Engine Coolant Anti Freeze Types'''
'''M-B Engine Coolant Anti Freeze Types'''
Line 13: Line 20:


http://www.benzworld.org/forums/w211-e-class/2209257-rust-water-pump-hint-failure-coolant.html?utm_medium=email&utm_source=201#post10680497
http://www.benzworld.org/forums/w211-e-class/2209257-rust-water-pump-hint-failure-coolant.html?utm_medium=email&utm_source=201#post10680497
'''DIY Coolant Change Basic Technique for Flushing and Refill'''
* ONLY open the system with engine temperature less than 90C, and do it SLOWLY.
* Drain old coolant using Radiator Drain Plug (and engine block drain plugs if they exist).
* Dispose of the Coolant per your Local regulations, even though it is classified as "Biodegradable".
* Fill with rain water using Vacuum Filling System to remove trapped air bubbles. (Takes about 6-7L.)
* Drain again.
* Repeat fill with rain water and drain several more times until drained fluid is clear. (On last few drains, use Vacuum System without filling to remove deep trapped air bubbles.)
* Then fill with distilled water using Vacuum Filling System. (Takes about 6-7L.)
* Drain once more. (Use Vacuum System several times without filling to remove deep trapped air bubbles.)
* If using M-B coolant add as much as system will take using Vacuum Filling System.
* If using antifreeze concentrate add 6L of concentrate using Vacuum Filling System.
* Top up with distilled water.
* After all air has escaped top up with either M-B coolant or distilled water as required.
* Final Concentration using antifreeze concentrate should be 6L in 11.2L ie 54%.
* Note if you do a "complete" coolant change every 2 - 3 years, there is probably no need to do the several rain water and distilled water flushes.
'''DIY Radiator Coolant and Pressure Test'''
http://www.benzworld.org/forums/w140-s-class/1444114-photo-diy-coolant-service-la-vacuum.html

Revision as of 14:55, 9 March 2015

Diagram of M113 Coolant Circuit

W220_M113_Diagram_of_Coolant_Circuit.JPG

M113 Coolant Change Interval

  • OEM Coolant is supposedly good for 250,000Km or 15 Years.
  • M-B DIY enthusiasts typically change the coolant every 3 - 5 years.

M113 Coolant Quantity Required

  • Cooling System Capacity is 11.2L.

M-B Engine Coolant Anti Freeze Types

  • BQ 1 03 0002 (G05) yellow M-B Sheet TBD
  • BQ 1 03 0004 (G48) dark blue/green M-B Sheet TBD
  • BQ 1 03 0005 (G??) pink M-B Sheet 325.5

MB_Coolant_BQ_1_03_0005_%28G48%29.JPG

M-B Article on Engine Coolant BQ 1 03 0005 (G48)

http://www.benzworld.org/forums/w211-e-class/2209257-rust-water-pump-hint-failure-coolant.html?utm_medium=email&utm_source=201#post10680497

DIY Coolant Change Basic Technique for Flushing and Refill

  • ONLY open the system with engine temperature less than 90C, and do it SLOWLY.
  • Drain old coolant using Radiator Drain Plug (and engine block drain plugs if they exist).
  • Dispose of the Coolant per your Local regulations, even though it is classified as "Biodegradable".
  • Fill with rain water using Vacuum Filling System to remove trapped air bubbles. (Takes about 6-7L.)
  • Drain again.
  • Repeat fill with rain water and drain several more times until drained fluid is clear. (On last few drains, use Vacuum System without filling to remove deep trapped air bubbles.)
  • Then fill with distilled water using Vacuum Filling System. (Takes about 6-7L.)
  • Drain once more. (Use Vacuum System several times without filling to remove deep trapped air bubbles.)
  • If using M-B coolant add as much as system will take using Vacuum Filling System.
  • If using antifreeze concentrate add 6L of concentrate using Vacuum Filling System.
  • Top up with distilled water.
  • After all air has escaped top up with either M-B coolant or distilled water as required.
  • Final Concentration using antifreeze concentrate should be 6L in 11.2L ie 54%.
  • Note if you do a "complete" coolant change every 2 - 3 years, there is probably no need to do the several rain water and distilled water flushes.

DIY Radiator Coolant and Pressure Test

http://www.benzworld.org/forums/w140-s-class/1444114-photo-diy-coolant-service-la-vacuum.html